
MaxiCut® Ultra™ (Sleeves) 89-5740CH
User information

Sizes
Size 7 (S) + Size 10 (XL) + Size 12 (XXXL)
Use
Cut resistant sleeve for Assured Protection™ in dry environments
Can be used to protect against contact heat up to 100°C for 15 sec. Not to be used for protection against naked flames.
Performance values are indicated in the table.
Typelist and performance values
| EN ISO 21420:2020+A1:2024 |
| EN 388:2016 + A1:2018: 2442C |
| EN 407:2020: X1XXXX |
Declarations
Category II
Medium risk
EU Declaration of conformity
ATG®, hereby declares, that this PPE Type is in conformity with the relevant Union harmonisation legislation: Regulation (EU) 2016/425 and the relevant harmonized standards (EN).Warnings
Does not protect against puncture through sharp objects such as needles or swarf.
This product is tear resistant and cannot be worn when using rotating machines or when there is a risk of entanglement in machine parts.
Do not use these gloves to protect against serrated edges or blades or naked flames.
Does not protect against liquids and/or chemicals.
Before use, inspect the product for any defects or imperfections and avoid wearing a damaged, heavily soiled, worn or dirty (also internally) product of any substance, this could irritate and/or infect the skin and cause dermatitis. In this event, seek medical advice from the company doctor or consult a dermatologist.
Sleeves do not replace wearing gloves. The sleeve should be worn with the knitwrist underneath the knitwrist of the cut resistant glove.
Remove contaminated sleeves.
Donning
Wash and dry your hands and forearms completely before donning the sleeves.
Slip into the sleeve from the top side until your thumb fits into the smaller whole on the other side where the thumb loop is pointing to.
Ensure the product fits well.
Doffing
Remove the sleeve by pulling the sleeve with 2 fingers from the wrist away from you. Repeat on the other arm.
After use, clean the product thoroughly with a dry cloth to remove any contaminants.
If the product has to be re-worn, store it in such a way that the inside lining of the support can dry out easily.
This product can be washed according to the care instructions.
Care instructions
Storage / Cleaning
Store the product in it's original packaging in a cool and dry place.
Keep away from direct sunlight, heat, flame and sources of Ozone.
Continued exposure to direct sunlight or excessive heat may shorten the lifetime and cause fading, discoloration and cracks in the product.
The product can be laundered at 40°C/104°F with a standard detergent (3 cycles), natural drying.
The product lifetime in use is based on wear and abrasion.
This product can be used until the expiry date displayed on the product stamp.
Disposal / Waste
Used products maybe contaminated with infectious or hazardous substances.
Dispose of according to the Local Authority/Municipality Regulations, landfill or incinerate under controlled conditions.
Explanation of the pictograms
| EN ISO 21420: General requirementsGeneral requirements |
| EN 388:2016 + A1:2018Mechanical Hazards
* coupe test results are only indicative while the TDM cut resistance test (ISO13997) is the reference performance result. |
| EN 407:2020Thermal Hazards (Heat/Fire)
Performance level 0 indicates that the product fails below the minimum performance level for the given individual hazard. |
| Production date MM/YYYY (month/year) |
| Expiry date MM/YYYY (month/year) |
Higher values stand for better protection/resistance. If “X” is marked as a performance level the test is either not applicable or not proceeded.
Puncture resistance should not be confused with piercing exerted by thin tips or needles.
HandCare®
Skin Health Alliance Dermatologically Accredited | Yes |
---|---|
REACH compliant | Yes |
OEKO-TEX® Standard 100 - 08.BH.57867 Hohenstein HTTI | Certified |
Washable | 40°C/104°F |
Constituents / Allergies
Some products may contain ingredients which are known to be a possible cause of allergies in sensitive persons who may develop irritant and/or allergic contact reactions.
Skin contact: if an allergenic reaction occurs seek medical advice immediately. Eye contact; rinse thoroughly with low pressure water. If any prolonged discomfort, seek medical advice immediately.
Warranty / limitation of damages
ATG® warrants that this product shall be in accordance with ATG® standard specifications as of the date of delivery to authorized distributors.
Except to the extent prohibited by law, this warranty is in line with all warranties, including any warranty of fitness for a particular purpose; ATG® liability shall be limited to the purchase price of the product at issue.
Buyers and users of this product are deemed to have accepted the terms of this limitation of warranty, which may not be varied by any verbal or written agreement.